Abstract
ABSTRACT The release of chromium, nickel, and manganese from knives stainless steel produced in Italy and People’s Republic of China was investigated with the aim to check their quality and compliance with Italian Ministerial Decree 21.03.73, which is the most detailed text for the hygiene regulation of packaging, containers, and tools intended for food contact. Temperature effect on metal release is investigated in 18 sets of knives. Tests are performed by simulating discontinuous contact using a 3% glacial acetic acid solution in distilled water at 50°C and 100°C. Chromium, nickel, and manganese quantification is performed by total reflection X-Ray fluorescence. Chemical composition highlights low sulphur content, and most of them belong to the American Iron and Steel Institute (AISI) 420 type A stainless steel group. Tests performed at 100°C revealed higher concentration of released metals. Only three knives tested at 100°C exceed the limit of 100 µg L−1.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.