Abstract

Ag-Cd and Ag-CdO contacts, made both by sintering and postoxidation, were evaluated as to their durability by inductive and capacitive overcurrent tests according to the IEC 328 and NBR 6269 standards. Materials transfer during electric tests were monitored at 10000, 20000, 30000, and 40000 switching operations by scanning electron microscopy (SEM), energy-dispersive X-ray analysis, and chemical analysis. Better performance with regard to erosion was found for Ag-CdO postoxidized contacts, compared with sintered ones. Structural changes on the surface of Ag-Cd and Ag-CdO contacts were studied by SEM. The surface of Ag-Cd contacts changed rather uniformly, while Ag-CdO contacts developed considerable inhomogeneity. Sintered and postoxidized contacts also have also different structures. Sintered Ag-CdO contacts show a matrix with pulverized droplets while postoxidized Ag-CdO show very little change.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.