Abstract

We present detailed studies on mesh refinement influence and cardiac-cycle flow periodicity in aorta flow analysis with isogeometric discretization. Both factors play a key role in the reliability and practical value of aorta flow analysis. The core computational method is the space–time Variational Multiscale (ST-VMS) method. The other key method is the ST Isogeometric Analysis (ST-IGA). The ST framework, in a general context, provides higher-order accuracy. The VMS feature of the ST-VMS addresses the computational challenges associated with the multiscale nature of the unsteady flow in the aorta. The ST-IGA provides smoother representation of the aorta and increased accuracy in the flow solution. We conduct the studies for a patient-specific aorta geometry. We determine the level of mesh refinement needed and assess the nature of the flow periodicity reached.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.