Abstract

Atomic force microscopy (АFМ) and high-precision scanning electron microscopy methods were used to study the surface of diffusion filter-membranes of alloy Pd93Y7. The formation of alterations in structure in one of membranes was established as a result from the homogenizing annealing at 900°C for 1 hours. It was found that the reversible doping of the membrane alloy with hydrogen caused the dispersion of the diffusion filter-membranes’ surface structure. Differences in changes by the surface structure are determined during the hydrogenation in directional and non-directional flow of hydrogen.