Abstract

Internal mechanical strain and defects in Si crystals implanted with Ge+ ions over the dose range 1010-3 × 1015 cm-2 have been studied. The strain after the annealing cycles was investigated by high-resolution x-ray diffraction; the defects with deep levels in the bandgap were investigated by deep level transient spectroscopy. In the as-implanted samples and at low annealing temperatures vacancy-related defect complexes with deep levels in the gap are associated with the mechanical strain induced by isolated amorphous inclusions. In the temperature range 500-900 °C the dominant defects are Ge-containing complexes. At high annealing temperatures (700-900 °C) deep level traps associated with the boundaries between the recrystallized regions and the rest of the crystal are formed and a corresponding strain profile is created.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.