Abstract

One of the limiting mechanisms of pressurized water reactor spent fuel cladding is creep owing to high temperature and rod internal pressure. Based on extensive studies, many countries have tentatively concluded that creep rupture is hard to occur under dry storage conditions and cannot severely degrade the integrity of the cladding if it meets the 400°C limitation owing to a self-limiting property. However, the changes in mechanical properties after creep deformation are not well understood due to the limited amount of relevant tests and analyses. In this regard, mechanical property degradation of unirradiated Zircaloy-4 cladding by creep deformation was investigated using a ring compression test and microscopic observation. In addition, the implication regarding spent fuel cladding integrity based on the test results is described.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.