Abstract

This article outlines the recycled aggregate replacement rate and thick-diameter rate of GFRP tube confined in recycled concrete, which has an important impact on the material's compressive strength. Overall, under the same conditions of using recycled concrete, the bearing capacity of short concrete columns can be improved by using broader GFRP tubes. There is a four-fold increase in the bearing capacity of short concrete columns compared to the short column without the restriction of a GFRP tube. The bearing capacity of a short column crafted by recycled coarse aggregate is much lower (about 30%). than those made by common concrete column Additionally, the bearing capacity of short columns made by recycled fine aggregates is also lower than those made by common concrete (approximately 20%). Finally, we find that there is no significant difference between experimental and theoretical data.