Abstract

The mechanical behavior of joints on lattice wind turbine tower of concrete-filled steel tubular(CFST) is very complex, the safety and reliability of joints is very important for the whole structure. To better understand the mechanical properties of the joints, we design a static loading test of 3 KT-type CFST joints. According to the test, we make analysis about the failure progress, equivalent stress of joint intersection and the relation of load-defomation. The results showed that due to the presence of concrete, the failure mode of CFST joints is web members failed. The failure characteristic of overlap joints is the instability of compression web member while the gap joints are the weld tear of tensile web member. With the increase of the overlap ratio, the distribution of the equivalent stress is more uniform. The high stress area is in the gap and the tower wall which between the crown point and saddle point in tensile side.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.