Abstract
Thermographic measurements at the ALT-II pump limiter on TEXTOR have been performed with the following results. (1) The design of the toroidal pump limiter provides a rather uniform temperature distribution and prevents an overheating of the graphite cover tiles. (2) The local measurements of the convective energy flux to the limiter (IR scanner) and of the radiated power (bolometer) show normally a good power balance; this indicates that the power is leaving the plasma toroidally symmetrically. (3) From the analysis of the temperature distribution in poloidal and toroidal direction along the ALT-II tiles a power decay length of 5–7 mm is derived. (4) The ion temperature at the last closed flux surface is obtained from the energy flux along the magnetic field lines. At low plasma densities, the ion temperature is up to a factor of 2 higher than the electron temperature and at high densities both temperatures converge to the same value.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.