Abstract

Abstract Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is used to quantify the blood–brain barrier (BBB) permeability–surface area product. Serial measurements can indicate changes in BBB health, of interest to the study of normal physiology, neurological disease, and the effect of therapeutics. We performed a scan–rescan study to inform both sample size calculation for future studies and an appropriate reference change value for patient care. The final dataset included 28 healthy individuals (mean age 53.0 years, 82% female) scanned twice with mean interval 9.9 weeks. DCE-MRI was performed at 3T using a 3D gradient echo sequence with whole brain coverage, T1 mapping using variable flip angles, and a 16-min dynamic sequence with a 3.2-s time resolution. Segmentation of white and grey matter (WM/GM) was performed using a 3D magnetization-prepared gradient echo image. The influx constant Ki was calculated using the Patlak method. The primary outcome was the within-subject coefficient of variation (CV) of Ki in both WM and GM. Ki values followed biological expectations in relation to known GM/WM differences in cerebral blood volume (CBV) and consequently vascular surface area. Subject-derived arterial input functions showed marked within-subject variability which were significantly reduced by using a venous input function (CV of area under the curve 46 vs. 12%, p < 0.001). Use of the venous input function significantly improved the CV of Ki in both WM (30 vs. 59%, p < 0.001) and GM (21 vs. 53%, p < 0.001). Further improvement was obtained using motion correction, scaling the venous input function by the artery, and using the median rather than the mean of individual voxel data. The final method gave CV of 27% and 17% in WM and GM, respectively. No further improvement was obtained by replacing the subject-derived input function by one standard population input function. CV of Ki was shown to be highly sensitive to dynamic sequence duration, with shorter measurement periods giving marked deterioration especially in WM. In conclusion, measurement variability of 3D brain DCE-MRI is sensitive to analysis method and a large precision improvement is obtained using a venous input function.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.