Abstract

ABSTRACT Water vapor transmission rate (WVTR) and water vapor permeability coefficient were measured at temperatures between 110 and 138°C using the modified cup method. The cup, placed in a Highly Accelerated Stress Test chamber, allowed water vapor to permeate the sample film attached to the cup. The WVTR was determined based on the increase in mass of the cup. To prevent sample damage during measurement, a cup with a pressure adjustment mechanism was utilized. Carrier-incorporated phosphorus pentoxide was used as the desiccant instead of anhydrous calcium chloride to ensure a consistent moisture absorption rate, especially at high temperatures. The water vapor permeability coefficients for the polycarbonate, polyimide, and adhesive films were distributed on an approximately straight line in the Arrhenius plot. Additionally, the Arrhenius plots for the polyethylene terephthalate and polyethylene naphthalate films captured the permeability bending point near the glass transition temperature. To accurately measure the high-temperatureWVTR, upper and lower limits were established for the weighing interval, cup mass gain, and WVTR measurement range.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.