Abstract

We tested 5 newly manufactured – prototype – 1013Ohm resistors in the feedback loop of Faraday cup amplifiers to measure small ion beams by Thermal Ionisation Mass Spectrometry (TIMS). The high Ohmic resistors installed in the TRITON Plus at the VU University Amsterdam theoretically have 10 times lower noise levels relative to the default 1011Ohm resistors. To investigate the precision and accuracy of analyses using these new amplifiers we measured Sr and Nd isotopes of reference standards at a range of ion currents (3.2×10−16 to 1×10−12A, corresponding to intensities of 32μV to 100mV on a default 1011Ohm amplifier) and on small amounts of material (100 and 10pg). Internal precision and external reproducibility for Sr and Nd isotope ratios are both better when collected on 1013 compared 1012Ohm resistors and to the default 1011Ohm resistors. At an 87Sr ion current of 3×10−14A (3mV on a 1011Ohm amplifier) the internal precision (2 SE) of 87Sr/86Sr is 5 times better for 1013Ohm resistors compared to 1011Ohm resistors. The external reproducibility (2 SD) at this beam intensity is 9 times better.Multiple 100 and 10pg Sr standards, ran to exhaustion, yielded low 87Sr/86Sr compared to the long term average (e.g. 10pg average=0.710083±164 (n=11) instead of 0.710244±12, n=73). The average off-set for 10pg standards can be explained by a loading blank contribution of 1.3pg. In contrast, Nd data on 100pg and 10pg samples are accurate suggesting that Nd loading blanks do not compromise the data. The external reproducibility of 143Nd/144Nd on 100pg samples is 125ppm and 3.3‰ on 10pg samples (2 RSD=relative standard deviation, n=10). Thus, variability in Nd and Sr isotope ratios in the 4th decimal place, e.g. 143Nd/144Nd 0.5110–0.5119 or 87Sr/86Sr 0.7100–0.7109, can be resolved in 10 to 100pg samples provided that the procedural blanks and chemical separation are optimal.For measurements in the beam intensity range usually covered by ion counting (<3mV or 2×105cps) we obtain a 143Nd/144Nd internal precision (2 SE) of 480ppm for a 143Nd intensity of 6.25×104cps (1mV) and 1% at an intensity of 2×103cps (32μV on a 1011Ohm amplifier). We find that at intensities higher than 2×104cps the precision using the 1013Ohm resistors is better than for ion counting owing to instability and non-linearity behaviour of the ion counting system. Our results indicate that between 2×104cps and an ion current of 2×10−13A (20mV on a 1011Ohm amplifier) it is beneficial to use the high gain amplifiers instead of (multi) ion counting or Faraday cups equipped with the standard 1011Ohm resistors. This finding suggests that the newly developed high gain resistors could potentially be valuable in applications that currently use (multiple) ion counting to measure small ion beams (e.g. U-series, Re-Os, Pu, Pb). In addition to improved precision, the use of Faraday cups equipped with high resistance amplifiers is more practical in terms of the required calibration procedure and in the flexibility in the collector set-up compared to using multiple ion counting arrays.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.