Abstract

In the prototype fast breeder reactor Monju, shielding measurements were made around the reactor core, the primary heat transport system (PHTS), and the fuel handling and storage system during the system start-up tests at different power levels between 0% and 45%. The objectives of the tests were to evaluate the margins by which the shielding performance exceeds the original design requirements, to demonstrate the validity of the shielding analysis method, and to acquire basic data for use in future FBR design. This paper summarizes the important features of the Monju shielding structures and the shielding measurements.