Abstract
This paper describes the shielding measurements results in the reactor head access area (RHAA) and the primary heat transport system (PHTS) cells performed during the power raising test periods from February through December, 1995 in the prototype fast breeder reactor Monju. We confirmed that the measured values were well below the shielding design requirements in the RHAA and the PHTS cells and that the countermeasures against neutron streaming to the RHAA and the PHTS cells were very effective. Future measurements in order to obtain basic data for use in future FBR design are planned for the next period of operation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.