Abstract

AbstractThree different test geometries were used to apply shear loading to fracture glass‐to‐metal joints typical of seals intended for use in planar solid oxide fuel cells (SOFCs): asymmetric compression; symmetric compression; and four‐point asymmetric bending. The measured apparent shear strengths were found to differ by an order of magnitude depending on the test configuration employed. In particular, the apparent shear strength measured in the asymmetric compression test was very low. Conversely, the highest apparent shear strengths were measured using the symmetric compression test and the four‐point asymmetric bend test gave an intermediate result. It is shown, by finite element modelling, that these differences are caused by differences in the normal stresses transverse to the joint. The locus of failure was always along the glass/metal interface in all test geometries. It is concluded that mechanical test procedures used to characterize glass‐ceramic seals in SOFC stacks need to be selected and interpreted with great care.