Abstract

The sources of uncertainty in measurement of large negative reactivity in WWER-440 by the inverse point kinetics method, are evaluated quantitatively on the example of measurement of the reactivity worth of the shutdown control rod system of WWER-440 at zero power. Considering the specific features of the control rod system of WWER-440, it is demonstrated that using an appropriate formulation of the inverse solution of the equations of point kinetics, the uncertainty of measured reactivity ρ/ β introduced by the assumption of constancy of the parameters of kinetics can be reduced to <3–5% for the case of the discussed rod-drop test at zero power. Based on an analysis of both numerically simulated and actual rod-drop transients, it is shown that the uncertainty of measured reactivity ρ/ β can be quite considerable due to the underlying delayed neutron data set—the values of ρ/ β obtained using different data sets can differ by ∼15%. Inexact accounting of the share of 239Pu in the fission neutron source is estimated to contribute to the total uncertainty of measured ρ/ β of ∼1%, whereas possible spatial effects are expected to result in a relative error in ρ/ β of ∼5%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.