We determined the vitamin B12 clearance using an ultrafiltration technique and assessed whether the clearance of this vitamin B12 could be used to estimate the glomerular filtration rate (GFR). Fourteen subjects (5 had renal disease, 7 had diabetes mellitus, one had liver cirrhosis and one had cholelithiasis) divided into two groups were studied (group 1, 5 patients without vitamin B12 preloading; group 2, 9 patients with vitamin B12 preloading). Vitamin B12 clearance was significantly correlated with inulin clearance (r = 0.81, p < 0.001) in group 1; group 2 showed an even better correlation (r = 0.94, p < 0.001) with the presaturated vitamin B12 binding protein. In group 2, the mean inulin and vitamin B12 clearance values do not differ significantly (40.3 +/- 13.6 vs 48.2 +/- 17.2 ml/min), but there was a significant difference between mean inulin and creatinine clearance (40.3 +/- 13.6 vs 64.9 +/- 19.9 ml/min, p < 0.05). In conclusion, vitamin B12 clearance appears to be a more reliable method of estimating GFR than creatinine clearance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.