Abstract
Forced Chemical Vapor Infiltration (FCVI) method was used in fabricating the Nicalon TM!Silicon Carbide composites. Both through-thickness and In-plane (fiber fabric plane) moduli were determined using ultrasonic techniques. The through-thickness moduli were found to be much less than the inplane moduli. Both in-plane and through-thickness moduli were significantly decreased with an increased porosity. The experimental results for the moduli were found to be in good agreement with a theoretical model.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.