Abstract

1291 is a radioisotope of iodine with a half-life of 15.7 My. In the pre-nuclear era, 129I resulted primarily from spontaneous fission of 23Su, and cosmic ray induced reactions with the xenon component of the atmosphere. In the post-nuclear era, anthropogenic 129I has resulted primarily from nuclear weapons testing, reprocessing of nuclear fuels, and accidental (example Chernobyl) or deliberate (activities of the former USSR in the Kara Sea) discharges of nuclear products into the environment. Potential uses of 129[ include monitoring of the environment around nuclear sites, as an oceanographic tracer, and as a retrospective proxy for 131I dispersion (Yiou et al., 1994). For many of these applications, the most relevant parameter is the ratio of 129I to stable iodine (1271) since this compensates for concentration and dilution processes in the hydrosphere and biosphere. In addition, use of the ratio 1291/1271 automatically takes into account the efficiency of extracting iodine from the samples. Because of its long half life, analysis of 129I by radioactive decay is inefficient. While other techniques such as neutron activation, classical mass spectrometry, and laser spectroscopy have been used, the most dramatic improvement has been the application of accelerator mass spectrometry (AMS) (Elmore et al., 1980, Kilius et al., 1990). Like classical mass spectrometry, AMS measures relative isotopic ratios, which are translated into absolute ratios by comparison with a standard. The compound that has been found to be most convenient for AMS analysis is AgI. In most environmental samples, the quantity of 127I in the sample is insufficient to give a quantity of AgI that is practical to manipulate. Therefore in general a few mg of carrier iodine is added at the beginning of the extraction process. However, if one wishes to have the 1291/~2rI ratio in the initial sample, it is necessary to make a separate determination of 127I in an aliquot of the sample before addition of the carrier. Also, one must take precautions to ensure isotopic homogenization of the carrier with 129I in the sample. Because of the potential volatility and multiple valence states of iodine, this is not always trivial especially for solid samples. It would thus be desirable to be able to make a carrier free determination of 1291/127I from environmental samples by AMS. The procedure described here was developed initially to measure 1291/1271 in sea water samples . In our normal procedure (Zhou, 1995) we generally use a 1 liter sample of ocean water, which typically contains ~50 ug of 127I and 10-100 fg of 129[. After taking a 10 ml aliquot for 1271 determination by colorimetry, we add -3 mg of carrier iodine. Because of its affinity for iodine, it occured to us that it might be possible to react 12 directly from sea water with metallic silver. To test this, we added 5 -10 mg of Ag powder (Goodfellow AG006020/21) to 250-1000 ml of acidified ocean water (to liberate 12). After agitation for several minutes, the solution was centrifuged and the Ag powder separated from the water. After washing the powder several times with distilled water, it was dried in an oven at 60~ The powder was then pressed into a 1 mm diameter, 1 mm deep hole in a support used as a cathode in our caesium sputter ion source (General Ionex model 846). Cathodes prepared in this way were found to give 30-600 nA of I for at least 30 minutes, ample time to complete AMS measurement. AMS measurements were carried out at the recently installed heavy ion line at the Tandetron based AMS facility at Gif sur Yvette. At the high energy end of the accelerator, the currents of I 5+ were 5 to 100 nA. Therefore, for samples having 1291/1271 ratios of 10 -1~ the 129[ count rate was generally a few counts per second. In addition to the much greater simplicity in preparing samples, this technique has several other advantages. (i) It avoids the necessity of a separate 1271 measurement. (ii) because of the simplified chemical treatment the potential for contamination is greatly reduced. (iii) it increases the measured ratio by almost 2 orders of magnitude, thus reducing the measuring time. (iv) the reduced beam intensity in our AMS system improves measurement precision.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call