Abstract

BackgroundMeasurement of direct oral anticoagulants (DOACs) concentration in patient blood is essential in special clinical circumstances. MethodsWe developed a fast, selective and sensitive method for simultaneous measurement of DOACs in human plasma consisting of an automated online solid-phase extraction method coupled with ultra-performance liquid chromatography electrospray ionization-tandem mass spectrometry (online SPE-UPLC-MS/MS). ResultsThe calibration curves of all DOACs were linear over the working range (apixaban: 0.25–760 μg/L, r > 0.99; dabigatran: 0.5–900 μg/L, r > 0.99; edoxaban: 0.6–800 μg/L, r > 0.99; rivaroxaban: 0.5–900 μg/L, r > 0.99). Limits of detection in the plasma matrix were < 0.2 μg/L, whereas the lower limits of quantification were < 0.6 μg/L for all DOACs. The intraassay and interassay CV for all DOACs were < 6%. Mean recoveries were between 61.4% and 91.6%. Method comparison between our online SPE-UPLC-MS/MS assay and commercially available functional based coagulation assays using patient samples showed a high degree of correlation for all investigated DOACs. ConclusionsWe developed and validated the first online SPE-UPLC-MS/MS method for fast, sensitive, specific, and reliable measurement of the new generation of DOACs and compared this method with commercial available coagulation assays.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call