Abstract

Direct Oral Anticoagulants (DOACs) available for the treatment and prevention of thromboembolic diseases include dabigatran, a direct thrombin (IIa) inhibitor, and apixaban, edoxaban and rivaroxaban, which are direct inhibitors of Stuart factor (Xa). DOACs have a different pharmacokinetic and pharmacodynamics profiles, with less probable drug-drug interactions than vitamin K antagonists. They do not require systematic therapeutic monitoring except in specific clinical situations such as emergency procedures or drug non-compliance. Furthermore, anticoagulant effects of DOACs could be impacted by renal impairment, drug-drug interactions, food interactions, or pharmacogenetic variability. In this context, we developed a method for simultaneous determination of dabigatran, rivaroxaban and apixaban in human plasma using high performance liquid chromatography coupled with a mass spectrometry assay and applied it to 26 patient samples. Our method presents a total run time of 5 min and extends from 25 to 1000 μg/L for apixaban and dabigatran; and from 5 to 1000 μg/L for rivaroxaban. Intra- and inter-assay accuracy were between −22.3 and 25.4%; and − 23.7 and 3.8%, respectively. Precision at low and high concentrations were below 17.5%. Frozen samples were stable up to 3 months. No significant cross-contamination was observed. In conclusion, our assay can be used during clinical studies and in daily routine practice for the management of specific clinical situations at reasonable cost.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call