Abstract

The influence of wood package design on airflow distribution was investigated for forced-air cooling using horticultural produce simulators. The position of grooves on the container walls was tested using slat width of 100–200 mm and airflow rates ranging from 0.0005 to 0.003 m 3 kg −1 s −1. The package opening configurations were compared based on their impact on the energy added to the system using a methodology previously developed. For this purpose, apples and sweet corns were taken as examples of produce from two different extremes in the respiration activity range. For airflow rates as low as 0.0005 m 3 kg −1 s −1one groove at the bottom of the container produced a cooling process more uniform than the other one-groove configurations and even two grooves because of natural convection effect. If packing low respiration rate produce, increasing airflow rate could compromise the process energy efficiency because of air circulation obstruction for less vented containers. For high respiration rate produce enlarging open area above 2.4% would be recommended rather than increasing airflow rate to enhance cooling energy efficiency.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.