Abstract

AbstractTo gain market share on product performance, suppliers will routinely specify product datasheet (DS) performance to tighter than six sigma specifications. To maintain quality levels in this instance, the product must be 100% tested in production to screen out parts that are outside specification. Because of test measurement error and temperature drift, the test limits (TLs) used must be guardbanded tighter than the DS limit to ensure that the shipped product meets the parts per million requirement. These guardbands are protection zones that protect the customer from receiving parts that are outside specification. A review of current guardbanding techniques finds that they are conservative in nature. New guardbanding models are presented, which calculate the limit sets required for production test, quality assurance test and DS limit specifications. These models account for both test measurement error and temperature drift. Model results show that the guardband required varies with Cpk of the TL, test measurement error and temperature correlation coefficient. Copyright © 2009 John Wiley & Sons, Ltd.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.