Pipe failure accidents (bulging, bursting) are frequent in thermal power plants, and severely influence the safe and economic running. The authors analyzed the possible causes and features of low-temperature superheater pipe bulging. Taking the low-temperature superheater pipe bulging accident in a power plant for an example, the authors conducted macroscopic topography analysis, running environment analysis, metallurgical analysis, chemical composition analysis and strength analysis of the bulged pipe. Paper’conclusion was that the cause of low-temperature superheater pipe bulging wasn’t superheating, and the cause of bulging was flame straightening of the pipe during installation. The paper's innovation is material and dynamics analysis of the accident cause.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.