Abstract

Two patients experienced an episode of massive air embolism during extracorporeal circulation. Several emergency measures were taken. (1) The roller pump was reversed to take out air from the aorta. (2) The circuit was disconnected and recirculated to eliminate air bubbles. (3) Perfusion was restarted and the patient cooled to 24°C for 40 minutes. (4) Pentothal (thiopental), steroids, and assisted ventilation were administered. The outcome was favorable in both patients, and there were no neurological sequelae. Immediate cooling and prolonged circulation seem to be a satisfactory approach to this problem.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.