Abstract
We have investigated porosity and permeability damage around perforations using a combination of transient analysis and X-ray CT. The method applied allowed us to perform the entire experiments on samples under simulated in-situ stress conditions and to map variations in permeability along the length of the core as well as with radial distance from the perforation. Berea (10.2-cm (4-in.) dia) cores saturated with low-viscosity silicone oil were perforated using conventional-shaped charges (6-g HMX) and API RP43 procedures by using 6.88-MPa (1000-psi) effective stress and 5.16-MPa (750-psi) and 2.61-MPa (350-psi) underbalance. Low-permeability Torrey Buff Sandstone was also perforated using 5.16-MPa (750-psi) underbalance. After sufficiently flowing the perforations, higher-viscosity silicone oil was injected. The movement of fluids was tracked using X-ray CT to measure the local velocity of the viscous fluid front at different locations along the perforation. Results of these tests were compared in terms of permeability and porosity damage. Quantitative analysis on Berea cores show, for the specific charge and test conditions used, that damage extends approximately 2 cm (0.78 in.) from the center of the perforation. Comparison of tests performed with 2.41-MPa (350-psi) and 5.16-MPa (750-psi) underbalance show a clear increase in permeability near the tunnel wall at the higher underbalance. A zone of somewhat-reduced permeability exists at approximately 1.7 cm from the perforation center in the latter case. Porosity profiles calculated show that porosity is almost uniform out from the tunnel and there is no compacted zone near the tunnel wall in liquid-saturated cores. However, there is a high-porosity zone from the tunnel wall out about 2 mm. This may be due to a region of circumferential partings and small cracks that lead to high porosity or due to the possible artifacts discussed in the paper. Qualitative results have also been obtained for a tight sandstone for which underbalance was insufficient to remove debris from the perforation tunnel. CT images reveal that the plugged tunnel acts as a conduit for fluid flow, showing that the plugging material has significantly higher permeability than the surrounding rock.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.