Abstract
Introduction: The treatment of chronic postdissection aneurysms of the aortic arch is a challenge. This study aims to describe false lumen management after aortic arch endovascular repair of post-type A dissection aneurysms treated with a branched endograft. Methods: In this single-center retrospective observational study, all consecutive patients undergoing endovascular treatment of aneurysmal degeneration of chronic type A aortic dissections following open repair were enrolled. The primary endpoint was maximal aortic diameter evolution measured on computed tomography angiography (CTA) performed during follow-up. Secondary endpoints included procedural success, aortic re intervention, and remodeling during follow-up. Results: Between January 2017 and June 2020, 22 patients underwent endovascular branched arch repair for post type A dissection aneurysms. Technical success was 100%. Thirteen patients (59%) had dissection involvement of at least 1 supra-aortic vessel. Midterm follow-up CTA was performed for 20 patients, 23.1 (±13.3) months after the procedure. Maximal aortic diameter at the level of the repair was decreasing in 13 (65%) patients, increasing in 2 (10%) patients, and no change was observed in 5 (25%) patients. During follow-up, 7 patients (35%) required aortic reintervention. Thoracic candy plugs were implanted for distal false lumen occlusion in 15 patients and associated with a high rate of complete remodeling (6/15 patients, 40%). Conclusion: Arch branch endografting of aneurysmal evolution of a post type A dissection aortic arch is a safe and feasible option in experienced hands. Candy plug use in favorable anatomies seems to be associated with accelerated remodeling of the aorta. Clinical Impact There are currently no recommendations on dissected supra- aortic vessels management and the use of thoracic aorta false lumen occlusion devices during endovascular repair of chronic post dissection aneurysm of the aortic arch with branched endografts. Based on our clinical experience reported in the current manuscript, we propose a treatment algorithm for the management of the false lumen in this setting.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.