Abstract

BackgroundA comprehensive malaria control intervention was initiated in February 2004 on Bioko Island, Equatorial Guinea. This manuscript reports on the continuous entomological monitoring of the indoor residual spray (IRS) programme during the first two years of its implementation.MethodsMosquitoes were captured daily using window traps at 16 sentinel sites and analysed for species identification, sporozoite rates and knockdown resistance (kdr) using polymerase chain reaction (PCR) to assess the efficacy of the vector control initiative from December 2003 to December 2005.ResultsA total of 2,807 and 10,293 Anopheles funestus and Anopheles gambiae s.l. respectively were captured throughout the study period. Both M and S molecular forms of An. gambiae s.s. and Anopheles melas were identified. Prior to the first round of IRS, sporozoite rates were 6.0, 8.3 and 4.0 for An. gambiae s.s., An. melas and An. funestus respectively showing An. melas to be an important vector in areas in which it occurred. After the third spray round, no infective mosquitoes were identified. After the first spray round using a pyrethroid spray the number of An. gambiae s.s. were not reduced due to the presence of the kdr gene but An funestus and An. melas populations declined from 23.5 to 3.1 and 5.3 to 0.8 per trap per 100 nights respectively. After the introduction of a carbamate insecticide in the second round, An. gambiae s.s. reduced from 25.5 to 1.9 per trap per 100 nights and An. funestus and An. melas remained at very low levels. Kdr was found only in the M-form of An. gambiae s.s. with the highest frequency at Punta Europa (85%).ConclusionAll three vectors that were responsible for malaria transmission before the start of the intervention were successfully controlled once an effective insecticide was used.Continuous entomological surveillance including resistance monitoring is of critical importance in any IRS based malaria vector control programme. This paper demonstrates that sufficient resources for such monitoring should be included in any proposal in order to avoid programme failures.

Highlights

  • A comprehensive malaria control intervention was initiated in February 2004 on Bioko Island, Equatorial Guinea

  • Continuous entomological surveillance including resistance monitoring is of critical importance in any indoor residual spray (IRS) based malaria vector control programme

  • Anopheles gambiae sensu stricto (s.s.), Anopheles melas and Anopheles funestus are responsible for malaria transmission on the island [3,4] resulting in entomological inoculation rates (EIR) of up to 281 and 787 infective bites per year for An. gambiae s.s. and An. funestus respectively [4]

Read more

Summary

Introduction

A comprehensive malaria control intervention was initiated in February 2004 on Bioko Island, Equatorial Guinea. This manuscript reports on the continuous entomological monitoring of the indoor residual spray (IRS) programme during the first two years of its implementation. Malaria is a major endemic disease in the Central African tropical island of Bioko, Equatorial Guinea. In February 2004, The Bioko Island Malaria Control Project (BIMCP) initiated a comprehensive malaria control intervention consisting of indoor residual spraying (IRS) and effective case management, funded by a consortium led by Marathon Oil Company in partnership with the government of Equatorial Guinea, Medical Care Development International (MCDI), One World Development Group (OWDG), Medical Research Council of South Africa (MRC) and Harvard University. The intervention was monitored by entomological, clinical and population indicators [2]

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call