Abstract

Since the main distribution line faults can be securely identified as outlined in the first and second paper, this third paper presents the methodology of localizing the main distribution line fault when broadband over power lines (BPL) networks have already been deployed across the distribution power grids. The main issue of this paper is the detailed presentation of the main line localization methodology (MLFLM) as well as well as its performance assessment when measurement differences occur. The contribution of this paper, which is focused on the application of MLFLM, is double. First, the procedure, which is followed in order to create the database of faults and is used by MLFLM, is here analytically presented. This database is based on the application of the main distribution line fault identification percentage metric (MDLFI) to coupling reflection coefficients of all possible fault OV MV BPL topologies (modified OV MV BPL topologies). Second, the performance assessment of MLFLM is investigated with respect to the nature of the measurement differences and the location of main distribution line faults across the distribution power grid.

Highlights

  • A major advantage of the broadband over power lines (BPL) networks is the fact that their development is simple and economically advantageous since their deployment is based on the already operating power grid infrastructure

  • It should be noted that the previous experience concerning the creation and management of databases, which has been obtained from the Topology Identification Methodology (TIM) of [22], [24] and Fault and Instability Identification Methodology (FIIM) of [25], [26], is exploited in Main Line Fault Localization Methodology (MLFLM)

  • The measurement differences that occur in overhead medium-voltage (OV MV) BPL networks during the determination of coupling reflection coefficients are typically described by continuous uniform distributions (CUD) with range from 0 to a maximum CUD value that is equal to αMD

Read more

Summary

Trends in Renewable Energy

Main Line Fault Localization Methodology in Smart Grid – Part 3: Main Line Fault Localization Methodology (MLFLM). The main issue of this paper is the detailed presentation of the main line localization methodology (MLFLM) as well as well as its performance assessment when measurement differences occur. The procedure, which is followed in order to create the database of faults and is used by MLFLM, is here analytically presented. This database is based on the application of the main distribution line fault identification percentage metric (MDLFI) to coupling reflection coefficients of all possible fault OV MV BPL topologies (modified OV MV BPL topologies). The performance assessment of MLFLM is investigated with respect to the nature of the measurement differences and the location of main distribution line faults across the distribution power grid

Introduction
OV MV BPL topology are equal to
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call