Abstract

These three papers cover the overall methodology for the identification and localization of faults that occur in main transmission and distribution lines when broadband over power lines (BPL) networks are deployed across the transmission and distribution power grids, respectively. In fact, this fault case is the only one that cannot be handled by the combined operation of Topology Identification Methodology (TIM) and Instability Identification Methodology (FIIM). After the phase of identification of main distribution line faults, which is presented in this paper, the main line fault localization methodology (MLFLM) is applied in order to localize the faults in overhead medium-voltage BPL (OV MV BPL) networks. The main contribution of this paper, which is focused on the identification of the main distribution line faults, is the presentation of TM2 method extension through the adoption of coupling reflection coefficients. Extended TM2 method is analyzed in order to identify a main distribution line fault regardless of its nature (i.e., short- or open-circuit termination). The behavior of the extended TM2 method is assessed in terms of the main line fault nature and, then, its results are compared against the respective ones during the normal operation, which are given by the original TM2 method, when different main distribution line fault scenarios occur. Extended TM2 method acts as the introductory phase (fault identification) of MLFLM.

Highlights

  • During the past few years, a tremendous development in the deployment of broadband over power lines (BPL) networks for enhancing the intelligence, stability and autonomy of the vintage power grid infrastructure has been witnessed [1], [2]

  • [6]-[10], [13]-[22], [32]-[34], the well-established hybrid method consists of: (i) a bottom-up approach that is based on the multiconductor transmission line (MTL) theory and eigenvalue decomposition (EVD) decomposition for the single-input single-output (SISO) systems of this paper; and (ii) a top-down approach that is denoted as TM2 method and is based on the concatenation of multidimensional chain scattering matrices

  • The identification of main distribution line faults is based on the coupling reflection coefficients derived from the original and the extended TM2 method as well as their differences

Read more

Summary

Trends in Renewable Energy

Main Line Fault Localization Methodology in Smart Grid – Part 1: Extended TM2 Method for the Overhead Medium-Voltage Broadband over Power Lines Networks Case. Received June 13, 2017; Accepted September 2, 2017; Published September 27, 2017 These three papers cover the overall methodology for the identification and localization of faults that occur in main transmission and distribution lines when broadband over power lines (BPL) networks are deployed across the transmission and distribution power grids, respectively. This fault case is the only one that cannot be handled by the combined operation of Topology Identification Methodology (TIM) and Instability Identification Methodology (FIIM).

Introduction
Transfer Functions and Reflection Coefficients
EVD modal reflection coefficient matrix
Conclusions
CONFLICTS OF INTEREST
Broadband over Power Lines Network Topologies by Applying Topology

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.