Axial hysteresis loops of glass-coated amorphous Fe 70B 15Si 10C 5 microwire have been measured as a function of both the diameter of metallic nucleus (from 3.7–14.9 μm) and the thickness of the coating (4.0–9.6 μm). They exhibit low-field rectangular hysteresis loops with a single and large Barkhausen jump even for samples as short as 5 mm long. Coercivity remarkably increases (roughly from 1 to 10 Oe) and remanence decreases (from 1 to 0.45 T), respectively, as the ratio of metallic nucleus radius to the total radius of the wire decreases from 0.63 to 0.16. The strength of the internal stresses induced during the fabrication depends on this ratio, and the easy axes of the corresponding magnetoelastic anisotropies determine the actual value of coercivity and remanence for these microwires.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.