The effect of field annealing (in direct (DC) or alternating current (AC) field) on the structure, magnetic properties and giant magnetoimpedance (GMI) of CuBe/ Fe19Co17Ni64 electroplated tubes was studied. The field and frequency dependences of total impedance and its real part were comparatively analyzed together with magnetization processes features. The GMI sensitivity with respect to an applied field was the subject of special attention in view of possible applications of these materials in small magnetic field sensors. The maximum GMI ratio depends strongly on the heat treatments. The DC field annealing leads to the highest total impedance GMI ratio (ΔZ/Z=250%) and real part of the total impedance GMI ratio (ΔR/R=640%), compared to as-cast and AC field annealed samples. The external field response of DC annealed samples presented a single peak GMI response as a consequence of a strong contribution of the longitudinal effective anisotropy. At the same time, the maximum obtained sensitivity of 13.5%/Oe for DC case is much lower compared to the highest sensitivity values obtained for as-prepared (28.6%/Oe) and DC field annealed (22.0%/Oe) tubes for the low frequency of 2.5MHz. The weak dependence of ΔZ/Z ratio in the case of AC field annealed samples in the high frequency range is an important advantage for particular sensor applications.