Abstract

The spectrum and the polarization of the magnetic flux density (B-field) of 6 induction heaters and 1 arc oven were measured by means of a PMM (Italy) spectrum analyser. The spectrum analysis showed that no substantial harmonics were observed while the polarization analysis revealed that the operator’s exposure was non-homogeneous within a distance of 1.5 m from the heater. When the distance was larger, the body was homogeneously exposed. In general we can state that the B-field strongly varied between heaters and that exposure exceeded the occupational reference levels recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) (1998) and European Directive 2004/40/EC in 5 of the 7 heaters. Within the framework of the Directive some protection actions should be taken. Whereas mitigation of existing/ old induction ovens is difficult, the design of new induction heaters and their housing should be based, among others, on electromagnetic reducing engineering concepts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call