Abstract
A 76-year-old woman with coronary artery disease status post coronary artery bypass grafting and paroxysmal atrial fibrillation and flutter status post cavotricuspid isthmus ablation underwent radiofrequency (RF) ablation of recurrent, symptomatic atrial tachycardia (AT) (cycle length [CL] 378 ms). High-density activation mapping using a Biosense Webster (Diamond Bar, CA) PentaRay® catheter revealed a macroreentrant circuit rotating clockwise (right anterior oblique, caudal view) along the right atrial free wall and conducting slowly through a narrow isthmus (zigzag line) (Figure 1A).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.