Abstract

Double-indicator dilution methods can be used for measurement of lung water. The thermal conductivity method is based on heat as a diffusible and conductivity as a non-diffusible indicator. In the present study we correlated lung thermal volume with gravimetrical measurement of extravascular lung water after thrombin-induced microembolization in dog lungs. The embolization was accompanied by significantly increased vascular permeability and accumulation of interstitial water. Under these conditions there was a close correlation between the two methods of measuring lung water (r = 0.78, p less than 0.01).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.