Abstract

BackgroundInhalation exposure to nanomaterials in workplaces can include a mixture of multiple nanoparticles. Such ambient nanoparticles can be of high dissolution or low dissolution in vivo and we wished to determine whether co-exposure to particles with different dissolution rates affects their biokinetics.Methods and ResultsRats were exposed to biosoluble silver nanoparticles (AgNPs, 10.86 nm) and to biopersistent gold nanoparticles (AuNPs, 10.82 nm) for 28 days (6-h/day, 5-days/week for 4 weeks) either with separate NP inhalation exposures or with combined co-exposure. The separate NPs mass concentrations estimated by the differential mobility analyzer system (DMAS) were determined to be 17.68 ± 1.69 μg/m3 for AuNP and 10.12 ± 0.71 μg/m3 for AgNP. In addition, mass concentrations analyzed by atomic absorption spectrometer (AAS) via filter sampling were for AuNP 19.34 ± 2.55 μg/m3 and AgNP 17.38 ± 1.88 μg/m3 for separate exposure and AuNP 8.20 ± 1.05 μg/m3 and AgNP 8.99 ± 1.77 μg/m3 for co-exposure. Lung retention and clearance were determined on day 1 (6-h) of exposure (E-1) and on post-exposure days 1, 7, and 28 (PEO-1, PEO-7, and PEO-28, respectively). While the AgNP and AuNP deposition rates were determined to be similar due to the similarity of NP size of both aerosols, the retention half-times and clearance rates differed due to the difference in dissolution rates. Thus, when comparing the lung burdens following separate exposures, the AgNP retention was 10 times less than the AuNP retention at 6-h (E-1), and 69, 89, and 121 times lower less than the AuNP retention at PEO-1, PEO-7, and PEO-28, respectively. In the case of AuNP+AgNP co-exposure, the retained AgNP lung burden was 14 times less than the retained AuNP lung burden at E-1, and 26, 43, and 55 times less than the retained AuNP lung burden at PEO-1, PEO-7, and PEO-28, respectively. The retention of AuNP was not affected by the presence of AgNP, but AgNP retention was influenced in the presence of AuNP starting at 24 h after the first day of post day of exposure. The clearance of AgNPs of the separate exposure showed 2 phases; fast (T1/2 3.1 days) and slow (T1/2 48.5 days), while the clearance of AuNPs only showed one phase (T1/2 .81.5 days). For the co-exposure of AuNPs+AgNPs, the clearance of AgNPs also showed 2 phases; fast (T1/2 2.2 days) and slow (T1/2 28.4 days), while the clearance of AuNPs consistently showed one phase (T1/2 54.2 days). The percentage of Ag lung burden in the fast and slow clearing lung compartment was different between separate and combined exposure. For the combined exposure, the slow and fast compartments were each 50% of the lung burden. For the single exposure, 1/3 of the lung burden was cleared by the fast rate and 2/3 of the lung burden by the slow rate.ConclusionsThe clearance of AgNPs follows a two- phase model of fast and slow dissolution rates while the clearance of AuNPs could be described by a one- phase model with a longer half-time. The co-exposure of AuNPs+AgNPs showed that the clearance of AgNPs was altered by the presence of AuNPs perhaps due to some interaction between AgNP and AuNP affecting dissolution and/or mechanical clearance of AgNP in vivo.

Highlights

  • Inhalation exposure to nanomaterials in workplaces can include a mixture of multiple nanoparticles

  • Silver nanoparticles are widely used as an antibacterial component in textiles, personal care products, cosmetics, home furnishing appliances, and biomedicine [1, 2], while gold nanoparticles are often used in biomedical fields, such as drug delivery, image diagnostics, and therapies [3,4,5]

  • While it is under revision, the newly revised OECD inhalation test guidelines included some portion of toxicokinetics such as lung burden measurement of particulate aerosols including nano-range aerosols

Read more

Summary

Introduction

Inhalation exposure to nanomaterials in workplaces can include a mixture of multiple nanoparticles. Recognizing the difference in toxicokinetic evaluation between conventional chemicals including pharmaceuticals and nanomaterials, the current OECD toxicokinetic test guideline 417 explicitly stated that the guideline is not intended for testing nanomaterials [8]. The recently revised OECD guidelines for subacute (TG 412) and subchronic (TG 413) inhalation toxicology testing stated that “testing of poorly soluble solid aerosols should include measurements of lung burden and clearance kinetics” [9, 10]. Such test guidelines require additional postexposure observation (PEO) periods that include lung burden measurements to inform on lung clearance behavior and translocation. In a previous toxicokinetic study, the current authors investigated the distribution (particulate or ionic) of AgNPs and

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call