Abstract

A long period grating (LPG) coated with polyvinyl alcohol has been developed and evaluated through exposure to a range of relative humidity (RH) levels (from 33%RH to 97%RH). The conditions for the creation of the sensor probes are described and the response of the device in terms of changes in the resonance loss of several of the spectral loss bands has been monitored. In order to make comparative measurements, a noncoated LPG was exposed to various known refractive index (RI) conditions and the grating response was monitored, analyzed and the results evaluated. This is then related to the change in RH when the sensor is exposed to various RH levels, as the coating RI changes, leading to the change in resonance loss. The PVA coated LPG sensor is showing a relatively fast response time of ~ 80 s to reach 97%RH from 33%RH and inducing ~ 2 dB change in transmission of resonance loss band.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.