Abstract

Tokamak Fusion Test Reactor (TFTR) deuterium neutral beams have been operated unintentionally with significant quantities of extracted water ions. Water has been observed with an optical multichannel analyzer. These leaks were thermally induced with the contamination level increasing linearly with pulse length. Up to 6% of the beam current was attributed to water ions, corresponding to an instantaneous value of 12% at the end of a 1.5 s pulse. A similar contamination is observed during initial operation of ion sources exposed to air. Operation of new ion sources typically produces a contamination level of ∼2%, with cleanup to undetectable levels in 50–100 beam pulses. Approximately 90% of the water extracted from ion sources with water leaks was deuterated, implying that there is the potential for tritiated water production during TFTR’s forthcoming DT operation. It is concluded that isotope exchange in the plasma generator takes place rapidly, most likely as the result of surface catalysis. The primary concern is with O implanted into beam absorbers recombining with tritium, and the subsequent retention of T2O on cryopanels.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.