Abstract

Classical DC current transformer, based on a linear amplifier as a compensating amplifier, is well known as a power inefficient device. If the linear amplifier is replaced with switching counterpart, significant power saving can be achieved. A natural choice for replacement can be found in a half-bridge class-D amplifier. However, the half-bridge class-D amplifier is prone to bus-pumping effect, and direct replacement cannot be performed in a straightforward manner. This study presents an analysis of power consumption issues and irregular behaviour for a DC current transformer, caused by the bus-pumping effect. For the case of DC current measurement, the main issues are explained, giving better insight into power consumption, and possible hazards to transformer circuitry. Presented analytical results are experimentally verified.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.