Abstract

This work aimed to study the effects of low dose irradiation in order to detect possible deviations from the linear-quadratic dose dependence of survival after charged particle irradiation. Survival of V79 cells at low doses was studied using a semi-automated cell detection system similar to the DMIPS system. With such a technique, the precision of survival measurements is improved by avoiding the stochastic uncertainties of the conventional dilution assay. A significant hypersensitivity at low doses (0.1 Gy) has been detected for 100 MeV/u carbon ions, whereas for higher doses (up to 0.5 Gy) a transition to a plateau-like region is observed, which is consistent with the assumption of induced resistance. These results are apparently in contrast to earlier studies using high-LET radiation like, e.g. neutrons or negative pions, where the effect of induced resistance has been reported to be at least significantly reduced for single exposure experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.