Abstract

Loop-mediated isothermal amplification (LAMP) is a novel molecular detection method that is more rapid and simpler than PCR. Products can be detected by turbidity using one temperature without the need for expensive PCR equipment. Our objective was to sensitively detect Salmonella Typhimurium from pork products within 1 d using the LAMP assay. Pork chop and pork sausage samples (25 g) were inoculated with high (10(8) to 10(6) CFU) and low (10(5) to 10(0) CFU) inocula of S. Typhimurium. Serial dilutions in phosphate buffered saline were plated on XLT4 agar either immediately or after selective preenrichment in tetrathionate broth (225 mL) for 10-h at 37 degrees C. Nucleic acid was extracted using the TRIzol method from 1-mL samples. The LAMP assay using 6 specific invA gene primers and Bst DNA polymerase reaction mix was carried out at 62 degrees C for 90 min in a waterbath. Turbid products were detected visually and by agarose gel electrophoresis. Improved Salmonella detection at 10(2) CFU/25 g for both pork chop and sausage was obtained after 10-h enrichment and 10(6) CFU/25 g without enrichment for both products. This assay can detect Salmonella from pork within 1 d, significantly faster than traditional methods that take >5 d. This method shows tremendous potential for routine diagnostics and monitoring of Salmonella by the pork industry. The novel loop-mediated isothermal amplification (LAMP) assay is a rapid, specific, and sensitive method that has potential application for routine diagnostics of Salmonella from pork products. The isothermal method does not require expensive equipment such as a PCR thermocycler but only a simple waterbath for amplification within 90 min. Detection is even simpler by visual eye or turbidimeters that are less expensive than fluorescent spectrophotometers or real-time PCR machines. All these advantages make it a practical approach for routine use by processing industries to rapidly detect Salmonella in their environment and to implement appropriate control strategies. To improve detection sensitivities, preenrichment followed by selective enrichment may be necessary. Even so, the entire assay can be completed at the most within two 8-h working shifts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.