Abstract
Loop-mediated isothermal amplification (LAMP) methods to detect chicken infectious anemia virus (CIAV), reticuloendotheliosis virus (REV), and Marek’s disease virus (MDV), and a reverse transcription (RT)-LAMP assay to detect infectious bursal disease virus (IBDV), were developed. The CIAV-LAMP, REV-LAMP, MDV-LAMP, and IBDV-RT-LAMP methods were performed using four sets of six primers targeting the VP1 gene of CIAV, the gp90 gene of REV, the Meq gene of MDV, and the VP2 gene of IBDV. The results (a change in color) were observed visually. The methods showed high specificity and sensitivity. The detection limits were 50 genomic copies of CIAV, 16 genomic copies of REV, 20 genomic copies of MDV, and 250 genomic copies of IBDV. When used to test clinical samples, the results of the LAMP assays were in 100% agreement with a previously described PCR. Therefore, the LAMP assays are simple, rapid, highly sensitive, and specific methods for detecting four immune-suppressive viruses.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.