Abstract

We report a high performance mid-infrared pump visible probe measurement system, which can measure phase-sensitive responses to a mid-infrared pulse along the oscillating electromagnetic field. In this system, the pump light is a phase-locked mid-infrared pulse with a temporal width of 100 fs, which is produced via difference frequency generation (DFG) from two idler pulses of two optical parametric amplifiers (OPAs) that are excited by the same Ti:sapphire regenerative amplifier. The probe pulse is a visible pulse with a temporal width of 9 fs and is generated from a custom-built non-collinear OPA. By measuring the electric-field waveforms of mid-infrared pump pulses with electro-optic sampling and evaluating their carrier envelope phase (CEP) and the temporal positions of their envelopes relative to ultrashort visible probe pulses, we are able to perform double feedback corrections that eliminate both the following sources of drift. The CEP drift in mid-infrared pulses originating from fluctuations in the difference of optical-path lengths of the two idler pulses before the DFG is corrected by inserting a wedge plate in one idler path, and the drift in pump–probe delay times due to fluctuations in the difference of the overall optical-path lengths of the pump and probe pulses is corrected with mechanical delay lines. In this double feedback system, the absolute carrier phase of mid-infrared pulses can be fixed within 200 mrad and errors in the measurement of phase-sensitive responses can be reduced to within 1 fs over a few tens of hours.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call