Abstract
We developed the theoretical basis for long-term determination of airborne concentrations of unattached and attached radon progeny. The work was separated into two parts. First, we showed that (stacked and multiply etched) LR 115 detectors could be used to determine airborne concentrations of the short-lived radon progeny, 218Po and 214Bi. The equilibrium factor F between radon and its progeny could then be determined through the use of the reduced equilibrium factor F red . The airborne concentrations of 214Pb could then be determined. Second, we developed a method based on the airborne concentrations of 218Po, 214Pb and 214Bi to determine the parameters of the Jacobi room model, viz., the ventilation rate λ v , aerosol attachment rate λ a , deposition rate of unattached progeny λ d u and the deposition rate of attached progeny λ d u . With these parameters, the unattached fraction f p of the potential alpha energy concentration could also be determined. Knowledge of f p , together with F, would enable more accurate determination of the effective dose in the human lung.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.