Abstract

Abstract Funding Acknowledgements Type of funding sources: Private company. Main funding source(s): Abbott. Introduction Automatic adjustment of atrioventricular delay (AVD) with SyncAV has been shown to improve electrical synchronization. However, the long term effects of SyncAV optimization on electrical synchrony are unknown. Purpose Evaluate the effect of SyncAV programming on 6-month (6mo) QRS duration during biventricular (BiV) and left ventricle only MultiPoint Pacing (MPP). Methods Patients with LBBB and QRS duration (QRSd) ≥ 150 ms scheduled for CRT-P/D device implantation with quadripolar LV lead were enrolled in this prospective study. QRSd was measured post-implant from 12-lead surface ECG by blinded experts during the following pacing modes: intrinsic conduction, MPP (MPP=RV+LV1+LV2) and LV-only MPP (LVMPP=LV1+LV2). For each mode, SyncAV was enabled (e.g. MPP+SyncAV) with the patient-tailored SyncAV offset that minimized QRSd. Patients were then randomized 1:1 to receive MPP+SyncAV or LVMPP+SyncAV with the optimal offset identified at implant, and QRSd was re-evaluated at the 6mo follow-up. Results Fifty-nine patients (72% male, 41% ischemic, 26% ejection fraction, 166 ms intrinsic QRSd) completed device implant and QRSd assessment. Relative to intrinsic conduction at implant, the MPP+SyncAV group (n=30) had a QRSd reduction of 26% at implant (162 to 122 ms, p<0.001), and 20% at 6mo (162 to 130 ms, p<0.001). The LVMPP+SyncAV group (n=29) had a QRSd reduction of 24% at implant (165 to 128 ms, p<0.001), and 15% at 6mo (165 to 140 ms, p<0.001). In the MPP+SyncAV group, 28/30 (93%) of patients had more than 10% reduction in QRSd with respect to intrinsic at implant, with 27/30 (90%) maintaining this trend at 6 mo follow up. With LVMPP+SyncAV pacing, only 25/29 (86%) of patients had more than 10% reduction in QRSd with respect to intrinsic at implant, and this reduced to 18/29 (62%) maintaining this trend at 6 mo follow up. Conclusion MPP combined with SyncAV significantly improved acute electrical synchrony at implant in CRT patients with LBBB, as assessed by QRSd reduction. Significant QRSd reduction was maintained at 6 months post-implant by both biventricular and LV-only MPP configurations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.