This study evaluated the long-term clinical performance of newly developed porcine bioprosthetic valves cross-linked with glutaraldehyde and polyepoxy compound for mitral valve replacement (MVR) in dogs. Five beagle dogs underwent MVR using the porcine bioprosthetic valves during cardiopulmonary bypass. Antithrombotic drugs were administered only for one month after MVR. Six months after MVR, transvalvular regurgitation was not observed in all dogs, paravalvular leakage was seen only in one dog. Twelve months after MVR, mild transvalvular regurgitations were observed in two dogs. Although diastolic atrioventricular pressure gradient was increased gradually, no significant differences were observed. Pressure half-time and valve area were within normal ranges as the bioprosthetic value. There was no clinical symptom of the thrombosis and the thrombogenesis was not observed in the porcine bioprosthetic valve and the annulus in all dogs for twelve months after MVR. The clinical findings suggest that antithrombogenicity of the valves were maintained, though the duability might not be enough in the long-term period.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.