Abstract

Porcine bioprosthetic valves cross-linked with glutaraldehyde and polyepoxy compound were newly developed for mitral valve replacement (MVR) in dogs. Five beagle dogs were performed a left thoracotomy and underwent MVR using the porcine bioprosthetic valves during cardiopulmonary bypass (CPB). A vein catheter inserted into right atrium and a vent catheter inserted into the right ventricle to drain. The hemodynamic conditions of CPB were excellent during surgery. The left atrial pressure was measured before and after MVR; there was no significant difference and it was normal. Thrombosis and the prosthetic valve regurgitation were not observed one week after MVR. Pressure half time (PHT) prolonged significantly (P<0.05) from 31.40 +/- 4.0 msec presurgery to 99.20 +/- 19.4 msec at seven days after MVR, although it indicated the normal range as the bioprosthetic valve. The symptom of the prosthetic valve failure was not observed. This study indicated that the MVR using porcine bioprosthetic valves under CPB might have been effective in dogs as a short-term evaluation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.