Abstract

The present study exposes an economical and easy-to-use system to assess the heat transfer in building envelopes by determining the U-value. Nowadays these systems require long wires and a host to collect and process the data. In this work, a multi-point system for simultaneous heat flux measurement has been proposed. The aim is to reduce the long measurement time and the cost of thermal isolation evaluations in large buildings. The system proposed consists of a low-cost 3D-printed heat flux sensor integrated with a LoRa transceiver and two temperature sensors. The heat flux (HF) sensor was compared and calibrated with a commercial HF sensor from the Fluxteq brand.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.