Abstract

Longitudinal heat conduction from surface to inside of solid material could be used to evaluate the subsurface defects. Considering that the skin depth of high frequency eddy current in metal is quite small, this paper proposed logarithmic analysis of eddy current thermography (ECT) to quantify the depth of subsurface defects. The proposed method was verified through numerical and experimental studies. In numerical study, ferromagnetic material and non-ferromagnetic material were both considered. Results showed that the temperature–time curve in the logarithm domain could be used to detect subsurface defects. Separation time was defined as the characteristic feature to measure the defect’s depth based on their linear relationships. The thermograms reconstructed by logarithm of temperature can improve defect detectability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.