Abstract

To assess the influence of locking plate and screw implants on postoperative infection rate in dogs >50 kg undergoing tibial plateau leveling osteotomy (TPLO). Retrospective case series. Dogs >50 kg (n = 208) that had TPLO. Medical records (January 2003-September 2011) were reviewed for dogs that had TPLO. Type of implant used (locking plate and screw fixation [LP] and dynamic compression plate and screw fixation [NLP]), use of postoperative antibiotics and presence of postoperative infection were recorded. Multivariate analysis was performed. Forty dogs (21.3%) had clinical signs compatible with postoperative infection. A positive microbiology swab was available in 16/40 cases (40%). Administration of postoperative antibiotics was associated with a lower incidence of infection (P = .006) and the use of NLP was associated with a higher incidence of infection (P = .01). Use of LP construct and postoperative antibiotic therapy significantly decreased infection rate in dogs >50 kg that have TPLO.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call